Abstract:Setting deformation theory of top and bottom layers caused by coal mining and rock and ore conductive factors as the basis, on the basis of the damage distribution, the roof and floor coal strata can be divided into many electrical sections, and geoelectric model can be established. Using ANSYS software for finite element analysis, through apparent resistivity contour map, apparent resistivity changing regularity caused by coal mining has been summarized and analyzed. Through analysis on the apparent resistivity change situation, a series of problems existed in coal mining can be solved. It will guide safe and high efficiency production in coal mine.